filename: tfs 1080a.doc version 1.2 25.04.2008 vi telefilter filter specification tfs 1080a 1/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@vectron.com vi telefilter reserves the right to make changes to the product(s) and/or information contained herein without notice. no liability is assumed as a result of their use or application. n o rights under any patent accompany the sale of any such product(s) or information. measurement condition ambient temperature: 23 c input power level: 0 dbm terminating impedance: input: 50 output: 50 characteristics remark: the reference level for the relative attenuation a rel of the tfs 1080a is the maximum attenuation in the pass band. the maximum attenuation in the pass band is defined as the insertion loss a e . the nominal frequency f n is fixed at 1080,0 mhz without any tolerance or li mit. the values of relative attenuation a rel are guaranteed for the whole operating temperature range. the frequency shift of the filter in the op erating temperature range is included in the production tolerance scheme. d a t a typ. value tolerance / limit insertion loss a e 3.3 db max. 5,0 db nominal frequency f n - 1080,0 mhz passband pb - f n 29,0 mhz pass band ripple p-p 0.69 db max. 1,0 db pass band variation p-p 0.46 db max. 1,0 db relative attenuation a rel 0,3 mhz ? 919 mhz 27.5 db min. 25 db 1240 mhz ? 2160 mhz 29.0 db min. 25 db 2160 mhz ? 2500 mhz 37.5 db min. 35 db group delay ripple within pb p-p * 6 ns max. 8 ns return loss 11 db min. 7 db input power level - max. 10 dbm operating temperature range otr - - 40 c ... + 85 c storage temperature range - - 40 c ... + 85 c temperature coefficient of frequency tc f ** 74 ppm/k - *) target is typ 5ns p-p ripple within passband aft er 3rd order detrend **) ? f(hz) =tc f (ppm/k) x(t-t 0 ) x f to (mhz) generated: checked / approved:
filename: tfs 1080a.doc version 1.2 25.04.2008 vi telefilter filter specification tfs 1080a 2/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@vectron.com vi telefilter reserves the right to make changes to the product(s) and/or information contained herein without notice. no liability is assumed as a result of their use or application. n o rights under any patent accompany the sale of any such product(s) or information. filter characteristic construction and pin connection (all dimensions in mm) 1 2 3 4 5 6 1,2 max. 0,6 0,1 0,75 3 0,15 0,6 1,5 1 3 6 4 date code 50 ohm test circuit l1 saw l2 2 5 1, 3, 4, 6 a80a w17 1 ground 2 input 3 ground 4 ground 5 output 6 ground date code: year + week w 2008 x 2009 a 2010 ... 25.0552 236.0441 447.0331 658.0221 869.011 1080 1290.989 1501.9779 1712.9669 1923.9559 2134.9448 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 frequency in mhz magnitude in db 1020 1040 1060 1080 1100 1120 1140 1160 -12 -10.8 -9.6 -8.4 -7.2 -6 -4.8 -3.6 -2.4 -1.2 0 frequency in mhz m a g n itu d e in d b 1020 1040 1060 1080 1100 1120 1140 1160 0 3 6 9 frequency in mhz v s w r
filename: tfs 1080a.doc version 1.2 25.04.2008 vi telefilter filter specification tfs 1080a 3/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@vectron.com vi telefilter reserves the right to make changes to the product(s) and/or information contained herein without notice. no liability is assumed as a result of their use or application. n o rights under any patent accompany the sale of any such product(s) or information. stability characteristics, reliability after the following tests the filter shall meet the whole specification: 1. shock: 500g, 1 ms, half sine wave, 3 shocks each plane; din iec 68 t2 - 27 2. vibration: 10 hz to 500 hz, 0,35 mm or 5 g respe ctively, 1 octave per min, 10 cycles per plan, 3 pl ans; din iec 68 t2 - 6 3. change of temperature: -55 c to 125c / 30 min. each / 1 0 cycles din iec 68 part 2 ? 14 test n 4. resistance to solder heat (reflow): reflow possible: three ti mes max.; for temperature conditions refer to the attached " air reflow temperature conditions" on page 4; this filter is rohs compliant (2002/95/eg, 2005/618 /eg) packing tape & reel: iec 286 ? 3, with exception of value f or n and minimum bending radius; tape type ii, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 9000 reel of empty components at start: min. 300 mm reel of empty components at start including leader : min. 500 mm trailer: min. 300 mm g do w ct f e g d1 p2 p1 po bo ao pull off direction pin marker typ date code ko t a c n w 1 w 2 the minimum bending radius is 45 mm. tape (all dimensions in mm) w : 8,00 0,3 po : 4,00 0,1 do : 1,50 +0,1/-0 e : 1,75 0,1 f : 3,50 0,05 g(min) : 0,75 p2 : 2,00 0,05 p1 : 4,00 0,1 d1(min) : 1,50 ao : 3,25 0,1 bo : 3,25 0,1 ct : 5,5 0,1 reel (all dimensions in mm) a : 330 w1 : 8,4 +1,5/-0 w2(max) : 14,4 n(min) : 50 c : 13,0 +0,5/-0,2
filename: tfs 1080a.doc version 1.2 25.04.2008 vi telefilter filter specification tfs 1080a 4/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@vectron.com vi telefilter reserves the right to make changes to the product(s) and/or information contained herein without notice. no liability is assumed as a result of their use or application. n o rights under any patent accompany the sale of any such product(s) or information. air reflow temperature conditions conditions exposure average ramp-up rate (30c to 217c) less than 3c/ second > 100c between 300 and 600 seconds > 150c between 240 and 500 seconds > 217c between 30 and 150 seconds peak temperature max. 260c time within 5c of actual peak temperature between 10 and 30 seconds cool-down rate (peak to 50c) less than 6c/second time from 30c to peak temperature no greater than 300 seconds temperature / c time / s max. 260c 217c 10 ... 30 s 30 ... 150 s max. 300 s chip-mount air reflow profile
filename: tfs 1080a.doc version 1.2 25.04.2008 vi telefilter filter specification tfs 1080a 5/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@vectron.com vi telefilter reserves the right to make changes to the product(s) and/or information contained herein without notice. no liability is assumed as a result of their use or application. n o rights under any patent accompany the sale of any such product(s) or information. history version reason of changes name date 1.0 - generation of development specification strehl 18.01.2008 1.1 - correct stopband attenuation frequencies s.springfeldt 15.02.2008 1.2 - generation of filter specification s.springfeldt 25.04.2008
|